COMPARISON DIAGNOSTIC ACCURACY OF ULTRASONOGRAPHY ELASTOGRAPHY FOR DETECTING LIVER FIBROSIS COMPARED TO LIVER BIOPSY: A COMPREHENSIVE SYSTEMATIC REVIEW AND META-ANALYSIS STUDIES

Authors

  • Arwan Firmansyah Faculty of Medicine, YARSI University, Special Region of Jakarta, Indonesia Author
  • Arya Utama Faculty of Medicine, YARSI University, Special Region of Jakarta, Indonesia Author

DOI:

https://doi.org/10.61841/eea7qz42

Keywords:

Ultrasonography elastography, liver fibrosis, liver biopsy

Abstract

Background: Liver fibrosis significantly impacts disease outcomes in chronic liver disease. While liver biopsy has long been the gold standard for assessing and staging fibrosis, non-invasive ultrasound-based methods are emerging as valuable alternatives. The aim of this study is to systematically review and conduct a meta-analysis to compare the diagnostic accuracy of ultrasound elastography with liver biopsy for detecting liver fibrosis based on literatures in the last 10 years.

Method: A systematic review and meta-analysis were conducted according to PRISMA 2020 guidelines using the PICO framework. Rigorous screening, data extraction, risk of bias assessment, and statistical analysis were performed to investigate diagnostic accuracy of ultrasonography elastography for detecting liver fibrosis compared to liver biopsy.

Results: A total of 32 articles were retrieved from online databases (PubMed, SagePub, Nature and Cochrane). After three rounds of screening, seven articles directly relevant to the meta-analysis were selected for full-text reading and analysis.

Conclusion: Liver fibrosis significantly impacts disease outcomes in chronic liver disease. While liver biopsy has long been the gold standard for assessing and staging fibrosis, non-invasive ultrasound-based methods like shear wave elastography are emerging as valuable alternatives.

References

Mendoza YP, Rodrigues SG, Delgado MG, et al. Inflammatory activity affects the accuracy of liver stiffness measurement by transient elastography but not by two-dimensional shear wave elastography in non-alcoholic fatty liver disease. Liver International. 2022;42(1):102-111. doi:10.1111/liv.15116

Cf D, J B, A B, et al. EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Long Version). Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2017;38(4). doi:10.1055/s-0043-103952

G F, Vw W, L C, et al. Liver Ultrasound Elastography: An Update to the World Federation for Ultrasound in Medicine and Biology Guidelines and Recommendations. Ultrasound in medicine & biology. 2018;44(12). doi:10.1016/j.ultrasmedbio.2018.07.008

Piscaglia F, Salvatore V, Mulazzani L, Cantisani V, Schiavone C. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage. Ultraschall Med. 2016;37(1):1-5. doi:10.1055/s-0035-1567037

Pavlov CS, Casazza G, Nikolova D, et al. Transient elastography for diagnosis of stages of hepatic fibrosis and cirrhosis in people with alcoholic liver disease. Cochrane Database Syst Rev. 2015;1(1):CD010542. doi:10.1002/14651858.CD010542.pub2

Berzigotti A, Tsochatzis E, Boursier J, et al. EASL Clinical Practice Guidelines on non-invasive tests for evaluation of liver disease severity and prognosis – 2021 update. Journal of Hepatology. 2021;75(3):659-689. doi:10.1016/j.jhep.2021.05.025

Lackner C, Tiniakos D. Fibrosis and alcohol-related liver disease. J Hepatol. 2019;70(2):294-304. doi:10.1016/j.jhep.2018.12.003

L P, H CP, F N, et al. Burden of liver disease in Europe: Epidemiology and analysis of risk factors to identify prevention policies. Journal of hepatology. 2018;69(3). doi:10.1016/j.jhep.2018.05.011

Cornberg M, Tacke F, Karlsen TH, European Association for the Study of the Liver. Clinical Practice Guidelines of the European Association for the study of the Liver - Advancing methodology but preserving practicability. J Hepatol. 2019;70(1):5-7. doi:10.1016/j.jhep.2018.10.011

Davison BA, Harrison SA, Cotter G, et al. Suboptimal reliability of liver biopsy evaluation has implications for randomized clinical trials. J Hepatol. 2020;73(6):1322-1332. doi:10.1016/j.jhep.2020.06.025

Lee MS, Bae JM, Joo SK, et al. Prospective comparison among transient elastography, supersonic shear imaging, and ARFI imaging for predicting fibrosis in nonalcoholic fatty liver disease. PLoS One. 2017;12(11):e0188321. doi:10.1371/journal.pone.0188321

Fang C, Sidhu PS. Ultrasound-based liver elastography: current results and future perspectives. Abdom Radiol (NY). 2020;45(11):3463-3472. doi:10.1007/s00261-020-02717-x

Cassinotto C, Boursier J, de Lédinghen V, et al. Liver stiffness in nonalcoholic fatty liver disease: A comparison of supersonic shear imaging, FibroScan, and ARFI with liver biopsy. Hepatology. 2016;63(6):1817-1827. doi:10.1002/hep.28394

Mulazzani L, Salvatore V, Ravaioli F, et al. Point shear wave ultrasound elastography with Esaote compared to real-time 2D shear wave elastography with supersonic imagine for the quantification of liver stiffness. J Ultrasound. 2017;20(3):213-225. doi:10.1007/s40477-017-0260-7

Schellhaas B, Strobel D, Wildner D, Goertz RS, Neurath MF, Pfeifer L. Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging? Eur J Gastroenterol Hepatol. 2017;29(6):723-729. doi:10.1097/MEG.0000000000000846

Barr RG. Shear wave liver elastography. Abdom Radiol (NY). 2018;43(4):800-807. doi:10.1007/s00261-017-1375-1

Cg F, A P, R L, et al. Comparative study between pSWE and 2D-SWE techniques integrated in the same ultrasound machine, with Transient Elastography as the reference method. Medical ultrasonography. 2020;22(1). doi:10.11152/mu-2179

I S, S B, O GT, R S, A P, A J. Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method? European journal of radiology. 2014;83(3). doi:10.1016/j.ejrad.2013.12.011

Atzori SM, Pasha Y, Maurice JB, Taylor-Robinson SD, Campbell L, Lim AKP. Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease. Digestive and Liver Disease. 2024;56(3):484-494. doi:10.1016/j.dld.2023.10.020

Conti F, Serra C, Vukotic R, et al. Assessment of Liver Fibrosis With Elastography Point Quantification vs Other Noninvasive Methods. Clinical Gastroenterology and Hepatology. 2019;17(3):510-517.e3. doi:10.1016/j.cgh.2018.06.027

Gharibvand MM, Asare M, Motamedfar A, Alavinejad P, Momeni M. Ultrasound shear wave elastography and liver biopsy to determine liver fibrosis in adult patients. Journal of Family Medicine and Primary Care. 2020;9(2):943. doi:10.4103/jfmpc.jfmpc_828_19

Tada T, Kumada T, Toyoda H, et al. Utility of real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C infection without cirrhosis: Comparison of liver fibrosis indices. Hepatology Research. 2015;45(10):E122-E129. doi:10.1111/hepr.12476

Zayadeen AR, Hijazeen S, Smadi M, et al. Comparing shear wave elastography with liver biopsy in the assessment of liver fibrosis at King Hussein Medical Center. Egypt Liver Journal. 2022;12(1):24. doi:10.1186/s43066-022-00186-z

Loomba R, Cui J, Wolfson T, et al. Novel 3D Magnetic Resonance Elastography for the Noninvasive Diagnosis of Advanced Fibrosis in NAFLD: A Prospective Study. Am J Gastroenterol. 2016;111(7):986-994. doi:10.1038/ajg.2016.65

A F, Me T, L Y, Kb C, A L, J B. Comparison of 2D Shear Wave Elastography, Transient Elastography, and MR Elastography for the Diagnosis of Fibrosis in Patients With Nonalcoholic Fatty Liver Disease. AJR American journal of roentgenology. 2020;214(1). doi:10.2214/AJR.19.21267

G X, S Z, X X, L Y, J Y, G W. Comparison of laboratory tests, ultrasound, or magnetic resonance elastography to detect fibrosis in patients with nonalcoholic fatty liver disease: A meta-analysis. Hepatology (Baltimore, Md). 2017;66(5). doi:10.1002/hep.29302

Yamaguchi R, Oda T, Nagashima K. Comparison of the diagnostic accuracy of shear wave elastography with transient elastography in adult nonalcoholic fatty liver disease: a systematic review and network meta-analysis of diagnostic test accuracy. Abdom Radiol. Published online September 6, 2024. doi:10.1007/s00261-024-04546-8

Downloads

Published

2024-10-21

How to Cite

Firmansyah, A. ., & Utama, A. . (2024). COMPARISON DIAGNOSTIC ACCURACY OF ULTRASONOGRAPHY ELASTOGRAPHY FOR DETECTING LIVER FIBROSIS COMPARED TO LIVER BIOPSY: A COMPREHENSIVE SYSTEMATIC REVIEW AND META-ANALYSIS STUDIES. Journal of Advanced Research in Medical and Health Science (ISSN 2208-2425), 10(10), 7-16. https://doi.org/10.61841/eea7qz42

Similar Articles

11-20 of 42

You may also start an advanced similarity search for this article.