THE ANALYSIS STUDY OF DIAGNOSTIC ACCURACY OF SINGLE SAMPLE RULE-OUT OF HIGH-SENSITIVITY CARDIAC TROPONIN IN DIAGNOSIS OF ACUTE MYOCARDIAL INFARCTION IN EMERGENCY DEPARTEMENT: A COMPREHENSIVE SYSTEMATIC REVIEW FROM LABORATORY DEPARTMENT

Authors

  • Laksmita Dwana Faculty of Medicine, Trisakti University, Special Region of Jakarta, Indonesia Author
  • Syifa Nabila Putri Faculty of Medicine, Trisakti University, Special Region of Jakarta, Indonesia Author

DOI:

https://doi.org/10.61841/khbzkn90

Keywords:

High-sensitivity cardiac troponin, acute myocardial infarction, single-sample rule-out

Abstract

Background: High-sensitivity cardiac troponin (hs-cTn) assays has significantly enhanced the diagnostic of acute myocard infark (AMI). Recent studies have shown that hs-cTn assays can effectively rule out AMI with a single sample. This systematic review aim to evaluate the diagnostic accuracy of single sample rule-out of high-sensitivity cardiac troponin in diagnosis of acute myocardial infarction in emergency departement based on literatures of the last 10 years.

Methods: The study adhered to PRISMA 2020 standards, examining English literature from 2014 to 2024. It excluded editorials, reviews from the same journal, and submissions without a DOI. PubMed, SagePub, SpringerLink, and Google Scholar were utilized as literature sources.

Result: Initially retrieving 360 articles from online databases (PubMed, SagePub, SpringerLink and Google Scholar) eight relevant papers were selected after three rounds of screening for full-text analysis.

Conclusion: High-sensitivity cardiac troponin I assays enable rapid AMI rule-out in emergency departments, offering high sensitivity and negative predictive value. However, caution is needed when ruling in AMI, and further research is required to optimize their use.

References

Zhelev Z, Hyde C, Youngman E, et al. Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ. 2015;350:h15. doi:10.1136/bmj.h15

Twerenbold R, Boeddinghaus J, Nestelberger T, et al. Clinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction. J Am Coll Cardiol. 2017;70(8):996-1012. doi:10.1016/j.jacc.2017.07.718

Clerico A, Zaninotto M, Aimo A, et al. Use of high-sensitivity cardiac troponins in the emergency department for the early rule-in and rule-out of acute myocardial infarction without persistent ST-segment elevation (NSTEMI) in Italy: Expert opinion document from the Study Group of Cardiac Biomarkers associated to the Italian Societies ELAS (European Ligand Assay Society, Italy Section), SIBIoC (Società Italiana di Biochimica Clinica), and SIPMeL (Società Italiana di Patologia Clinica e Medicina di Laboratorio). Clin Chem Lab Med CCLM. 2022;60(2):169-182. doi:10.1515/cclm-2021-1085

Wu AHB. A practical guide to the implementation of high-sensitivity cardiac troponin assays into the clinical lab. J Lab Precis Med. 2023;8(0). doi:10.21037/jlpm-22-61

Sandoval Y, Smith SW, Love SA, Sexter A, Schulz K, Apple FS. Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial Infarction. Am J Med. 2017;130(9):1076-1083.e1. doi:10.1016/j.amjmed.2017.02.032

Boeddinghaus J, Nestelberger T, Twerenbold R, et al. High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction. Clin Chem. 2019;65(7):893-904. doi:10.1373/clinchem.2018.300061

Greenslade J, Cho E, Van Hise C, et al. Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation. Clin Chem. 2018;64(5):820-829. doi:10.1373/clinchem.2017.283887

Body R, Burrows G, Carley S, et al. High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation. Clin Chem. 2015;61(7):983-989. doi:10.1373/clinchem.2014.231530

Mueller-Hennessen M, Lindahl B, Giannitsis E, et al. Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction. Int J Cardiol. 2019;276:261-267. doi:10.1016/j.ijcard.2018.10.084

Giannitsis E, Slagman A, Hamm CW, Gehrig S, Vollert JO, Huber K. Copeptin combined with either non-high sensitivity or high sensitivity cardiac troponin for instant rule-out of suspected non-ST segment elevation myocardial infarction. Biomarkers. 2020;25(8):649-658. doi:10.1080/1354750X.2020.1833084

Chapman AR, Mills NL. High-sensitivity cardiac troponin and the early rule out of myocardial infarction: time for action. Heart. 2020;106(13):955-957. doi:10.1136/heartjnl-2020-316811

Lopez-Ayala P, Boeddinghaus J, Koechlin L, Nestelberger T, Mueller C. Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays. Clin Chem. 2021;67(1):114-123. doi:10.1093/clinchem/hvaa226

Westwood M, van Asselt T, Ramaekers B, et al. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2015;19(44):1-234. doi:10.3310/hta19440

Joyce LR, Pickering JW, Than M. Ruling out acute myocardial infarction based on a single high-sensitivity troponin measurement in the emergency department: a clinical practice review. J Lab Precis Med. 2023;8(0). doi:10.21037/jlpm-23-20

Giuliani S, Dieplinger B, Mueller T. Head-to-head comparison of three different high-sensitivity cardiac troponin assays for early rule-in and rule-out of acute myocardial infarction. J Lab Precis Med. 2019;4(0). doi:10.21037/jlpm.2018.12.07

Twerenbold R, Boeddinghaus J, Nestelberger T, et al. How to best use high-sensitivity cardiac troponin in patients with suspected myocardial infarction. Clin Biochem. 2018;53:143-155. doi:10.1016/j.clinbiochem.2017.12.006

Ricci F, Neumann JT, Rübsamen N, et al. High-sensitivity troponin I with or without ultra-sensitive copeptin for the instant rule-out of acute myocardial infarction. Front Cardiovasc Med. 2022;9. doi:10.3389/fcvm.2022.895421

Rubini Gimenez M, Twerenbold R, Jaeger C, et al. One-hour Rule-in and Rule-out of Acute Myocardial Infarction Using High-sensitivity Cardiac Troponin I. Am J Med. 2015;128(8):861-870.e4. doi:10.1016/j.amjmed.2015.01.046

Boeddinghaus J, Nestelberger T, Koechlin L, et al. Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I. J Am Coll Cardiol. 2020;75(10):1111-1124. doi:10.1016/j.jacc.2019.12.065

van der Linden N, Wildi K, Twerenbold R, et al. Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Circulation. 2018;138(10):989-999. doi:10.1161/CIRCULATIONAHA.117.032003

Pickering JW, Greenslade JH, Cullen L, et al. Validation of presentation and 3 h high-sensitivity troponin to rule-in and rule-out acute myocardial infarction. Heart. 2016;102(16):1270-1278. doi:10.1136/heartjnl-2015-308505

Jaeger C, Wildi K, Twerenbold R, et al. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am Heart J. 2016;171(1):92-102.e5. doi:10.1016/j.ahj.2015.07.022

Fabre-Estremera B, Smith SW, Sandoval Y, et al. Rapid Rule-Out of Myocardial Infarction Using a Single High-Sensitivity Cardiac Troponin I Measurement Strategy at Presentation to the Emergency Department: The SAFETY Study. Clin Chem. 2023;69(6):627-636. doi:10.1093/clinchem/hvad033

Body R, Morris N, Collinson P. Single test rule-out of acute myocardial infarction using the limit of detection of a new high-sensitivity troponin I assay. Clin Biochem. 2020;78:4-9. doi:10.1016/j.clinbiochem.2020.02.014

Nowak RM, Christenson RH, Jacobsen G, et al. Performance of Novel High-Sensitivity Cardiac Troponin I Assays for 0/1-Hour and 0/2- to 3-Hour Evaluations for Acute Myocardial Infarction: Results From the HIGH-US Study. Ann Emerg Med. 2020;76(1):1-13. doi:10.1016/j.annemergmed.2019.12.008

Reichlin T, Twerenbold R, Wildi K, et al. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. Can Med Assoc J. 2015;187(8):E243-E252. doi:10.1503/cmaj.141349

Downloads

Published

2024-08-12

How to Cite

Dwana, L. ., & Putri, S. N. . (2024). THE ANALYSIS STUDY OF DIAGNOSTIC ACCURACY OF SINGLE SAMPLE RULE-OUT OF HIGH-SENSITIVITY CARDIAC TROPONIN IN DIAGNOSIS OF ACUTE MYOCARDIAL INFARCTION IN EMERGENCY DEPARTEMENT: A COMPREHENSIVE SYSTEMATIC REVIEW FROM LABORATORY DEPARTMENT. Journal of Advanced Research in Medical and Health Science (ISSN 2208-2425), 10(8), 1-10. https://doi.org/10.61841/khbzkn90

Similar Articles

21-30 of 187

You may also start an advanced similarity search for this article.