THE ANALYSIS STUDY OF DIAGNOSTIC ACCURACY OF SINGLE SAMPLE RULE-OUT OF HIGH-SENSITIVITY CARDIAC TROPONIN IN DIAGNOSIS OF ACUTE MYOCARDIAL INFARCTION IN EMERGENCY DEPARTEMENT: A COMPREHENSIVE SYSTEMATIC REVIEW FROM LABORATORY DEPARTMENT
DOI:
https://doi.org/10.61841/khbzkn90Keywords:
High-sensitivity cardiac troponin, acute myocardial infarction, single-sample rule-outAbstract
Background: High-sensitivity cardiac troponin (hs-cTn) assays has significantly enhanced the diagnostic of acute myocard infark (AMI). Recent studies have shown that hs-cTn assays can effectively rule out AMI with a single sample. This systematic review aim to evaluate the diagnostic accuracy of single sample rule-out of high-sensitivity cardiac troponin in diagnosis of acute myocardial infarction in emergency departement based on literatures of the last 10 years.
Methods: The study adhered to PRISMA 2020 standards, examining English literature from 2014 to 2024. It excluded editorials, reviews from the same journal, and submissions without a DOI. PubMed, SagePub, SpringerLink, and Google Scholar were utilized as literature sources.
Result: Initially retrieving 360 articles from online databases (PubMed, SagePub, SpringerLink and Google Scholar) eight relevant papers were selected after three rounds of screening for full-text analysis.
Conclusion: High-sensitivity cardiac troponin I assays enable rapid AMI rule-out in emergency departments, offering high sensitivity and negative predictive value. However, caution is needed when ruling in AMI, and further research is required to optimize their use.
References
Zhelev Z, Hyde C, Youngman E, et al. Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ. 2015;350:h15. doi:10.1136/bmj.h15
Twerenbold R, Boeddinghaus J, Nestelberger T, et al. Clinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction. J Am Coll Cardiol. 2017;70(8):996-1012. doi:10.1016/j.jacc.2017.07.718
Clerico A, Zaninotto M, Aimo A, et al. Use of high-sensitivity cardiac troponins in the emergency department for the early rule-in and rule-out of acute myocardial infarction without persistent ST-segment elevation (NSTEMI) in Italy: Expert opinion document from the Study Group of Cardiac Biomarkers associated to the Italian Societies ELAS (European Ligand Assay Society, Italy Section), SIBIoC (Società Italiana di Biochimica Clinica), and SIPMeL (Società Italiana di Patologia Clinica e Medicina di Laboratorio). Clin Chem Lab Med CCLM. 2022;60(2):169-182. doi:10.1515/cclm-2021-1085
Wu AHB. A practical guide to the implementation of high-sensitivity cardiac troponin assays into the clinical lab. J Lab Precis Med. 2023;8(0). doi:10.21037/jlpm-22-61
Sandoval Y, Smith SW, Love SA, Sexter A, Schulz K, Apple FS. Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial Infarction. Am J Med. 2017;130(9):1076-1083.e1. doi:10.1016/j.amjmed.2017.02.032
Boeddinghaus J, Nestelberger T, Twerenbold R, et al. High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction. Clin Chem. 2019;65(7):893-904. doi:10.1373/clinchem.2018.300061
Greenslade J, Cho E, Van Hise C, et al. Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation. Clin Chem. 2018;64(5):820-829. doi:10.1373/clinchem.2017.283887
Body R, Burrows G, Carley S, et al. High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation. Clin Chem. 2015;61(7):983-989. doi:10.1373/clinchem.2014.231530
Mueller-Hennessen M, Lindahl B, Giannitsis E, et al. Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction. Int J Cardiol. 2019;276:261-267. doi:10.1016/j.ijcard.2018.10.084
Giannitsis E, Slagman A, Hamm CW, Gehrig S, Vollert JO, Huber K. Copeptin combined with either non-high sensitivity or high sensitivity cardiac troponin for instant rule-out of suspected non-ST segment elevation myocardial infarction. Biomarkers. 2020;25(8):649-658. doi:10.1080/1354750X.2020.1833084
Chapman AR, Mills NL. High-sensitivity cardiac troponin and the early rule out of myocardial infarction: time for action. Heart. 2020;106(13):955-957. doi:10.1136/heartjnl-2020-316811
Lopez-Ayala P, Boeddinghaus J, Koechlin L, Nestelberger T, Mueller C. Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays. Clin Chem. 2021;67(1):114-123. doi:10.1093/clinchem/hvaa226
Westwood M, van Asselt T, Ramaekers B, et al. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2015;19(44):1-234. doi:10.3310/hta19440
Joyce LR, Pickering JW, Than M. Ruling out acute myocardial infarction based on a single high-sensitivity troponin measurement in the emergency department: a clinical practice review. J Lab Precis Med. 2023;8(0). doi:10.21037/jlpm-23-20
Giuliani S, Dieplinger B, Mueller T. Head-to-head comparison of three different high-sensitivity cardiac troponin assays for early rule-in and rule-out of acute myocardial infarction. J Lab Precis Med. 2019;4(0). doi:10.21037/jlpm.2018.12.07
Twerenbold R, Boeddinghaus J, Nestelberger T, et al. How to best use high-sensitivity cardiac troponin in patients with suspected myocardial infarction. Clin Biochem. 2018;53:143-155. doi:10.1016/j.clinbiochem.2017.12.006
Ricci F, Neumann JT, Rübsamen N, et al. High-sensitivity troponin I with or without ultra-sensitive copeptin for the instant rule-out of acute myocardial infarction. Front Cardiovasc Med. 2022;9. doi:10.3389/fcvm.2022.895421
Rubini Gimenez M, Twerenbold R, Jaeger C, et al. One-hour Rule-in and Rule-out of Acute Myocardial Infarction Using High-sensitivity Cardiac Troponin I. Am J Med. 2015;128(8):861-870.e4. doi:10.1016/j.amjmed.2015.01.046
Boeddinghaus J, Nestelberger T, Koechlin L, et al. Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I. J Am Coll Cardiol. 2020;75(10):1111-1124. doi:10.1016/j.jacc.2019.12.065
van der Linden N, Wildi K, Twerenbold R, et al. Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Circulation. 2018;138(10):989-999. doi:10.1161/CIRCULATIONAHA.117.032003
Pickering JW, Greenslade JH, Cullen L, et al. Validation of presentation and 3 h high-sensitivity troponin to rule-in and rule-out acute myocardial infarction. Heart. 2016;102(16):1270-1278. doi:10.1136/heartjnl-2015-308505
Jaeger C, Wildi K, Twerenbold R, et al. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am Heart J. 2016;171(1):92-102.e5. doi:10.1016/j.ahj.2015.07.022
Fabre-Estremera B, Smith SW, Sandoval Y, et al. Rapid Rule-Out of Myocardial Infarction Using a Single High-Sensitivity Cardiac Troponin I Measurement Strategy at Presentation to the Emergency Department: The SAFETY Study. Clin Chem. 2023;69(6):627-636. doi:10.1093/clinchem/hvad033
Body R, Morris N, Collinson P. Single test rule-out of acute myocardial infarction using the limit of detection of a new high-sensitivity troponin I assay. Clin Biochem. 2020;78:4-9. doi:10.1016/j.clinbiochem.2020.02.014
Nowak RM, Christenson RH, Jacobsen G, et al. Performance of Novel High-Sensitivity Cardiac Troponin I Assays for 0/1-Hour and 0/2- to 3-Hour Evaluations for Acute Myocardial Infarction: Results From the HIGH-US Study. Ann Emerg Med. 2020;76(1):1-13. doi:10.1016/j.annemergmed.2019.12.008
Reichlin T, Twerenbold R, Wildi K, et al. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. Can Med Assoc J. 2015;187(8):E243-E252. doi:10.1503/cmaj.141349
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Laksmita Dwana, Syifa Nabila Putri (Author)
This work is licensed under a Creative Commons Attribution 4.0 International License.
Licensing
Ninety Nine Publication publishes articles under the Creative Commons Attribution 4.0 International License (CC BY 4.0). This licensing allows for any use of the work, provided the original author(s) and source are credited, thereby facilitating the free exchange and use of research for the advancement of knowledge.
Detailed Licensing Terms
Attribution (BY): Users must give appropriate credit, provide a link to the license, and indicate if changes were made. Users may do so in any reasonable manner, but not in any way that suggests the licensor endorses them or their use.
No Additional Restrictions: Users may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.