THE EFFECT OF IMPLANT NUMBER, DISTRIBUTION WITH DIFFERENT ATTACHMENTS ON THE RETENTION AND STABILITY OF IMPLANT SUPPORTED OVERDENTURE

Authors

  • Areej Mufeed Abdulamajeed Dept. of prosthetic, College of Dentistry/ Mosul University, Iraq Author
  • Radhwan H. Hasan Dept. of prosthetic, College of Dentistry/ Mosul University, Iraq Author

DOI:

https://doi.org/10.53555/nnmhs.v3i9.616

Keywords:

Overedentur retention, Ball attachment, Implant number

Abstract

Background: It was stated that the “PREVENTION IS BETTER THAN CURE”    

Today, with the more attention on preventive measures in prosthodontics, the use of implant supported overdenture has increased to the point where it is now a feasible alternative to most treatment plan outlines in the construction of prosthesis for patients (Sheldon Winkler, 2009).  

Objective: Evaluate the effect of number and distribution of an implant upon in vitro retention and stability of a simulated implant-supported overdenture.  

Methods: In this in-vitro experimental study a model simulating a mandibular edentulous ridge with 7 dental implants analogs inserted in the model approximating the tooth position in the natural dentition was constructed. A two overdenture housing for each type of attachment made of acrylic resin with three hooks attach to occlusal surface of it which connected to three chains attached to a force gauge testing machine was used to measure peak load (N) required to disconnect (dislodge) an attachment in three directions vertical, rotational and oblique. Two different type of attachments have been studied (Ball, Locator). This study was aimed to evaluate retention and stability of implant-retained overdentures based upon implant number and distribution.  

Result: One way ANOVA analysis of variance test indicated that there were significant differences at P<0.05, using Duncan`s Multiple Range Test for comparison among the groups of Ball and Locator attachment indicated that groups of multi-implants recorded the significantly higher measured peak load  

(N) in the three directions of dislodgement  

Conclusion: variation in implant`s number and distribution affect the retention and stability of implant supported overdenture according to type of attachment utilized. 

References

.Dostálová T, Radina P, Seydlová M, Zvárová J, Valenta Z. (2009): Overdenture – Implants versus Teeth –Quality of Life and Objective Therapy Evaluation. Prague Medical Report; 110 (4): 332–342.

.Wolfart S, Brunzel S, Freitag S, Kern M. (2004): Assessment of dental appearence following changes in incisor angulation. Int J Prosthodont; 17: 150-4.

.Brunello DL, Mandikos MN. (1998): Construction faults, age, gender and relative medical health: Factors associated with complaints in complete denture patients. J Prosthet Dent; 79: 545-54.

.Laurina L, Soboleva U. (2006): Construction faults associated with complete denture wearers' complains. Stomatologija, Baltic Dental and Maxillofacial Journal; 8: 61-4.

.Hatim N. A, Mohammed S. (2011): Solving Complete Denture Problems by The Use of Overdenture: Clinical Case Report. Al–Rafidain Dent J; 11(2): 238-243.

.Mahesh L. Kurtzman G. Silverstein L and Gupta V. (2011): Restoring Facial Aesthetics and Function with Implant Overdentures. CPOI; 2(2): 6-12.

.Timmerman R, Stoker GT, Wismeijer D, Oosterveld P, Vermeeren JI, van Waas MA. (2004): An eight-year followup to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures. J Dent Res; 83: 630-3.

.Shor A, Goto Y, Shor K. (2007): Mandibular two-implant-retained overdenture: prosthetic design and fabrication protocol. Compend Contin Educ Dent; 28: 808.

.Petropoulos V.C, Smith W. (2002): Maximum Dislodging Forces of Implant Overdenture Stud Attachments. The International Journal of Oral & Maxillofacial Implants; 17(4): 526-535.

. Bagde A. D, Jaju S. B , Patil P. G. (2013): A Review on FEM Analysis of Mandibular Overdenture Implant. International Journal of Innovative Research in Science, Engineering and Technology; 2(6): 2137-2144.

. Lewandowski JA, White KC, Moore D, Johnson CJ. (1988): An investigation of two rare earth magnetic systems by measuring grip force and reseating force. J Prosthet Dent; 60: 705–711.

. Carr AB, McGivney GP, Brown DT. (2005): McCracken’s Removable Partial Prosthodontics. 11th ed. Elsevier Mosby; 23-25

. Scherer M.D, McGlumphy E.A, Seghi R.R, Wayne V. Campagni W.V. (2013): Comparison of Retention and Stability of Implant-Retained Overdentures Based upon Implant Number and Distribution. Int J Oral Maxillofac Implants; 28(6): 1-10.

. Fatalla AA, Song K, Du T, Cao Y. (2012): An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures. J Huazhong Univ Sci Technolog Med Sci; 32: 124-9 [15]. Ben-Ur Z, Gorfil C, Shifman A. (1996): Anterior implant-supported overdentures. Quintessence International; 27: 603–6.

. Feine JS, Carlsson GE, et al. (2002): The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology; 19: 3-4.

. Meijer HJ, Raghoebar GM, Batenburg RH, Visser A, Vissink A. (2009): Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial. Clinical Oral Implants Research; 20: 722–8.

. Mericske-Stern, R.D, Taylor, T.D, Belser U. (2000): Management of the edentulous patient. Clinical Oral Implants Research; 11(1): 108–125.

. Meghea D.M, Preoteasa C.T, Preoteasa E. (2014): Attachment Systems for Implant Overdentures. Literature Review. Romanian Journal of Oral Rehabilitation; 6(4): 52.

. Alsabeeha N, Atieh M, Swain MY, Payne AG. (2010): Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs. Int J Prosthodont; 23: 160166.

. Ahmedzadeh A, fereidoonpoor N. (2012): Comparison of Retentive Force in Four Attachment Systems in Implant- Supported Overdenture of the Lower Arch. J Dent Shiraz Uni Med Science; 13(2): 54-58

. Krennmair G, Seemann R, Fazekas A, Ewers R, Piehslinger E. (2012): Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial. Int J Oral Maxillofac Implants; 27(6): 1560-8 23.Sadig W. A. (2009): comparative in vitro study on the retention and stability of implant-supported overdentures. Quintessence Int; 40(4): 313-9.

Downloads

Published

2017-09-30

How to Cite

Abdulamajeed, A. M., & Hasan, R. H. (2017). THE EFFECT OF IMPLANT NUMBER, DISTRIBUTION WITH DIFFERENT ATTACHMENTS ON THE RETENTION AND STABILITY OF IMPLANT SUPPORTED OVERDENTURE . Journal of Advanced Research in Medical and Health Science (ISSN 2208-2425), 3(9), 5-16. https://doi.org/10.53555/nnmhs.v3i9.616

Similar Articles

71-80 of 83

You may also start an advanced similarity search for this article.